Product information:

■Meet the test requirements of general electrical safety standards such as IEC60335.1, UL60335.1, GB4706.1, etc.
■ Up to 100 groups of test condition memory, model of each group can be set, easy to find, test data can be saved via USB(optional)
■ Voltage ramp-up and ramp-down functions to meet the requirements of new industry standards;
■ Breakdown current upper and lower limit preset, intelligent judgment;
■ Digital closed-loop feedback control mode, automatic voltage regulation mode, automatic correction of output voltage/current, and not affected by the external power grid, ensuring the accuracy of the test

■ High-definition LCD display and simple panel operation

Technical Parameters:

Model SC536A
Test Contents AC and DC withstand voltage, insulation resistance
Data storage method USB (optional)
External interface Alarm LAMP, PLC, RS-232
AC withstand voltage
Output voltage setting range / accuracy AC 200~5000V

±(1.5%×setting+5digits)

Breakdown current measurement range / accuracy 0.10~100.0mA

±(1.5%×setting+5digits)

Breakdown current preset alarm range Upper limit :0.1~100.0mA;

Lower limit :0.00~5.00mA

Test time range / resolution 1~300s 1s/step
DC withstand voltage
Output voltage setting range / accuracy DC 200~5000V ±(1.5%× setting +5 digits )
Breakdown current measurement range / accuracy 0.10~10.00mA ±(1.5%×display+5 digits)
Breakdown current preset alarm range Upper limit: 0.10~10.00mA; lower limit: 0.00~5.00mA
Test time range / resolution 1~300s 1s/step
Insulation resistance
Output voltage setting range / accuracy DC500/1000V ±(1.5%× reading +5 digits )
Insulation resistance measurement range / accuracy 1~2000MΩ:

≤100MΩ:± (5%×display+3 digits )

>100 MΩ:± (8%× display +8 digits)

Insulation resistance alarm setting range  

Upper limit: 0 ~ 2000MΩ; lower limit: 1 ~ 2000MΩ

Test time range / resolution  

1~300s 1s/step

Equipment dimensions 435MM(W)*150MM(H)*550MM(D)
Equipment weight Approx. 30KGS
Equipment accessories Power cord*1, high voltage probe*1, test wire*1, fuse*1

External Wire Connection:

First confirm the power supply standard, AC 220V±10%,50Hz±5%,single-phase; the fuse standard: 5A,slow-blow. Note: terminals on the power supply connection box are marked as: output L, input N, GBI+,GBU+, earth connection clamps are marked GBU-,GBI-, connect the corresponding terminals on the rear panel when use.

Electrical Safety AC DC High Voltage And Insulation Resistance Tester 0

Graph: SC536A Wire Connection

Electrical Safety AC DC High Voltage And Insulation Resistance Tester

 

Electrical Safety AC DC High Voltage And Insulation Resistance Tester

 

Electrical Safety AC DC High Voltage And Insulation Resistance Tester

 

 

 

Tags: Electrical Test Equipment, Electrical Appliance Tester, IEC Test Equipment

滚动至顶部